Electronic Controlled Pattern Sewing Machine (PLK-G Series)
Troubleshooting — Electronic pattern sewing machine PLK-G2008H —
Please click each question item.
When the power is turned ON, “E-060 PF axis origin point sensor error” is displayed.
-
①Check if air is supplied adequately to the sewing machine's main body.
-
②Is the sensor ON? Check the sensor.
Click here for checking the input signal at sewing enabled condition.
The presser foot moves during thread cutting operation.
Check if the USTP code is entered after the TRIM code through the program settings of operational panel.
Thread cut operation does not initiate.
Are the setting data and step data installed correctly?
Perform importing from the USB memory for initial setting that comes with the product.
“M-043 Start prohibited signal is detected” is displayed.
-
①Is the turning switch in the manual mode (MANUAL)?
Set the turning switch to the automatic mode (AUTOMATIC).
Click here for automatic (normal mode)/manual (test mode) turning switch.
-
②Is the sensor holding in the correct position?
Check it is holding on the correct position.
Click here for checking the input signal at sewing enabled condition.